More details on this product
Buy Now
Features:
- For use in institutions, schools, universities, commercial buildings where heavy duty reliable operation is a requirement
- Rail assemblies and end caps are brass, bronze or stainless steel and rail travels in direction of the door swing
- Trims are thru bolted for additional security
- UL Listed for Panic and UL10C, UBC 7-2-1997 codes
- UL Listed for Fire Exit Hardware. 3 hours
- (A) label rating on pairs of doors up to 8′0″ x 8′0″ swinging in same or opposite directions
- Uncompromising security and safety in single and double fire exit doors
- Chassis mounted unit construction. Rim and vertical rod devices are nonhanded and easily reversible.
- Available in many different functions. Lever and escutcheon trims are grade 1 construction with clutch freewheeling mechanism. Rose and escutcheon covers 161 cut out.
9800 & F9800 Series Specifications
- For Doors - 1-3/4″ thick standard optional 2-1/4″ thick. 4-1/2″ minimum stile width required for single or double door application using standard 239 strike and pull or lever, thumbpiece and escutcheon trims.
- Chassis - Nonferrous ally (Panic Grade), steel (Fire Grade)
- Cover - Brass, bronze or stainless steel. Covers stock hollow metal doors with 161 cutout.
- Mounting - Furnished with wood and machine screws. Available with thru bolts on request. Thru bolts are included and standard packaging on fire rated devices.
- End Cap - Brass, bronze or stainless steel construction.
- Alarm - Available. See Alarm Exit Hardware section.
- Hand - Available. See Alarm Exit Hardware section.
- Latch Bolt - Stainless steel 3/4″ throw.
- Spring - Stainless steel throughout.
- ANSI Standard - A156.3, Grade 1.
- Rail Assembly - Heavy gauge brass, bronze or stainless steel.
- Strike - 239 packed standard (See Strike Page).
- Dogging Feature - Allen-type key furnished standard on non-fire labeled devices. Cylinder dogging available.
- Mullion - Available.
- UL and ULC Listed - 9800 Series for panic. F9800 Series for fire exit hardware for all types or 4′ x 8′ single doors and 8′ x 8′ double doors for up to 3 hour fire labeled installations, conforms to standards UL10C and UBC 7-2-1997 codes.
- Finish - Architectural plated finishes. See bottom of Alarm Exit Hardware for available finishes.
- Door Size - 9800E036 and F9800E036 for 36″ doors. 9820E048 and F9820E048 for 48″ doors.

- 3/4″ Stainless Steel Latchbolt
- Casted Chasis & Ass’y
- Push Rail
- Mounting Rail
- Sliding Shim
- End Cap
|
Item# |
Description for Non Fire Rated |
Satin Stainless Steel |
Polished Brass, Oil Rubbed Bronze, Satin Brass, Satin Bronze |
|
9800EO36 |
Rim Exit Only For 36” Wide Door. |
331.00 |
359.00 |
|
9820EO48 |
Rim Exit Only For 48” Wide Door. |
352.00 |
380.00 |
|
ALRM9820EO36 |
Alarm Rim Exit Only For 36” Wide Door. |
449.00 |
476.00 |
|
ALRM9820EO48 |
Alarm Rim Exit Only For 48” Wide Door. |
470.00 |
498.00 |
|
Description for Fire Rated |
Satin Stainless Steel |
Price for Aluminu`m, Polished Brass, Oil Rubbed Bronze, Satin Brass, Satin Bronze |
|
|
F9800E036 |
Rim Exit Only For 36” Wide Door. |
390.00 |
418.00 |
|
F9820EO48 |
Rim Exit Only For 48” Wide Door. |
411.00 |
439.00 |
|
FALM9820EO36 |
Alarm Rim Exit Only For 36” Wide Door. |
507.00 |
536.00 |
|
FALM9820EO48 |
Alarm Rim Exit Only For 48” Wide Door. |
527.00 |
555.00 |
9860 & F9860 Series Exit Devices
- For Doors - 1-3/4″ thick standard optional 2-1/4″ thick. 3-3/4″ minimum stile width required for single door application. 3-1/2″ minimum stile width required for double door application. Lover, thumbpiece and escutcheon trims available.
- Chassis - Nonferrous ally (Panic Grade), steel (Fire Grade)
- Cover - Brass, bronze or stainless steel. Covers stock hollow metal doors with 161 cutout.
- Mounting - Furnished with wood and machine screws. Thru bolts are standard packaging on fire rated devices. Thru bolts are included and standard packaging on fire rated devices.
- End Cap - Brass, bronze or stainless steel construction.
- Alarm - Available. Prefix “Alrm” before part #.
- Hand - Easily field reversible. Specify at time of order LHRB, RHRB for convenience.
- Latch Bolt - Stainless steel.
- Spring - Stainless steel.
- ANSI Standard - A156.3, Grade 1.
- Rail Assembly - Heavy gauge brass, bronze or stainless steel.
- Strike - See Strike page.
- Dogging Feature - Allen-type key furnished standard on non-fire labeled devices. Cylinder dogging available.
- Mullion - Available.
- UL and ULC Listed - 9860 Series for panic. F9860 Series for fire exit hardware for all types of 8′ x 8′ double doors for up to 3 hour fire labeled installations, conforms to standards UL10C and UBC 7-2-1997 codes.
- Finish - Architectural plated finishes. See bottom of Alarm Exit Hardware for available finishes.
- Door Size - 9860V3694 and F9860V3684 for 36″ x 84″ doors. 9880V4896 and F9880V4896 for 48″ x 96″ doors. 9890V3696 and F9890V3696 for 36″ x 96″ doors. 9850V36120 for 36″ x 120″ doors. 9840V48120 for 48″ x 120″ doors.
|
Item# |
Description for Non Fire Rated |
Satin Stainless Steel |
Polished Brass, Oil Rubbed Bronze, Satin Brass, Satin Bronze |
|
9860V3684 |
Surface Vertical Rod 36” Wide- 84” High *SH |
437.00 |
467.00 |
|
9890V3696 |
Surface Vertical Rod 36” Wide- 96” High *SH |
467.00 |
496.00 |
|
9850V36120 |
Surface Vertical Rod 36” Wide- 120” High *SH |
496.00 |
544.00 |
|
9880V4896 |
Surface Vertical Rod 48” Wide- 96” High *SH |
467.00 |
496.00 |
|
9840V48120 |
Surface Vertical Rod 48” Wide- 120” High *SH |
496.00 |
544.00 |
| FIRE RATED | |||
|
F9860V3684 |
Surface Vertical Rod 36” Wide- 84” High *SH |
501.00 |
530.00 |
|
F9890V3696 |
Surface Vertical Rod 36” Wide- 96” High *SH |
530.00 |
559.00 |
|
F9880V4896 |
Surface Vertical Rod 48” Wide- 96” High *SH |
530.00 |
559.00 |